0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G6E-134P-US DC12

G6E-134P-US DC12

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    DIP5

  • 描述:

    Signal Relay 12VDC 3A SPDT(16x10x8)mm THT

  • 数据手册
  • 价格&库存
G6E-134P-US DC12 数据手册
G6E Low Signal Relay Subminiature, Sensitive SPDT Signal Switching Relay • High sensitivity: 98-mW (Rated power consumption: 200mW) pickup coil power. • Impulse withstand voltage of 1,500V (10×160 μs) meets FCC requirements. • Stick packing employed in consideration of supporting automatic implementation. • Plastic-sealed model that allows automatic soldering. • New series of ultrasonically cleanable models is available. • Standard model conforms to UL/CSA standards. RoHS Compliant ■Model Number Legend ■Application Examples • • • • G6E-@ -@ @@ @ @ -@ -@ — ————— — — 1 2 3 4 5 6 7 8 7. Approved Standards US: UL, CSA UL: FILE No.E41515 CSA: FILE No.LR31928 4. Enclosure Rating 4: Fully sealed 1. Relay Function None: Single-side stable U : Single-winding latching K : Double-winding latching ( 5. Terminals Shape P: PCB terminals 2. Number of poles/ Contact Form 1: 1-pole/SPDT (1c) G 6 E ) 8. Special Function None : Standard U : For ultrasonically cleanable 6. Classification None : Standard L : Low sensitivity coil (400 mW) 3. Contact Type 3: Bifurcated crossbar Ag (Au-Alloy) contact Telecommunication equipment Office automation machines Industrial equipment Security equipment ■Ordering Information ●Standard Models (UL, CSA certified) Relay Function Classification Contact form SPDT (1c) Single-side stable Standard Model Rated coil voltage G6E -134P-US Single-winding latching Low-sensitivity Rated coil voltage Model Double-winding latching Standard Standard Rated coil voltage Model Low-sensitivity Rated coil voltage Model 5 VDC 5 VDC 5 VDC 5 VDC 6 VDC 6 VDC 6 VDC 6 VDC 9 VDC 12 VDC G6E -134PL-US 24 VDC 48 VDC G6EU -134P-US 9 VDC 12 VDC 12 VDC 24 VDC − G6EK -134P-US 9 VDC − Model G6EK -134PL-US 12 VDC 24 VDC − − Minimum packing unit 5 VDC 9 VDC 24 VDC − Rated coil voltage 6 VDC − 12 VDC 25 pcs/tube 24 VDC − − − ●Models for Ultrasonically Cleanable Relay Function Classification Contact form Single-side stable Standard Model Rated coil voltage Model 5 VDC 6 VDC SPDT (1c) G6E -134P-US-U Single-winding latching Double-winding latching Standard Standard Low-sensitivity 9 VDC 12 VDC Model 5 VDC G6E -134PL-US-U 24 VDC 48 VDC Rated coil voltage − − 12 VDC − Model 5 VDC G6EU -134P-US-U − − 12 VDC − − Rated coil voltage Minimum packing unit 5 VDC G6EK -134P-US-U − 24 VDC − Rated coil voltage − − 12 VDC 25 pcs/tube 24 VDC − − Note: When ordering, add the rated coil voltage to the model number. Example: G6E-134P-US DC5 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. 1 G6E Low Signal Relay ■Ratings ●Coil: Single-side Stable Classification Rated voltage Rated current (mA) 5 VDC 40.0 125 6 VDC 33.3 180 9 VDC 22.2 405 12 VDC 16.7 720 24 VDC 8.3 2,880 48 VDC 8.3 5,760 Standard Coil resistance (Ω) 5 VDC 79.4 63 6 VDC 66.6 90 9 VDC 44.3 203 12 VDC 33.3 360 24 VDC 16.7 1,440 Low-sensitivity Must operate Must release voltage voltage (V) (V) Max. voltage (V) % of rated voltage 70% max. 10% min. 70% max. 10% min. Power consumption (mW) 190% (at 23°C) Approx. 200 170% (at 23°C) Approx. 400 170% (at 23°C) Approx. 400 ●Coil: Single-winding latching Contact type G 6 E Rated voltage Rated current (mA) 5 VDC 40.0 Bifurcated crossbar Must set voltage Must reset voltage (V) (V) Coil resistance (Ω) Max. voltage (V) % of rated voltage Power consumption Set coil (mW) Reset coil (mW) Approx. 200 Approx. 200 125 6 VDC 33.3 180 9 VDC 22.2 405 12 VDC 16.7 720 24 VDC 8.3 2,880 70% max. 70% max. 190% (at 23°C) ●Coil: Double-winding latching Rated current (mA) Classification Coil resistance (Ω) Rated voltage Set coil Reset coil 5 VDC 40.0 40.0 125 125 6 VDC 33.3 33.3 180 180 9 VDC 22.2 22.2 405 405 12 VDC 16.7 16.7 720 720 2,880 Standard Set coil Reset coil 24 VDC 8.3 8.3 2,880 5 VDC 79.4 79.4 63 63 6 VDC 66.6 66.6 90 90 9 VDC 44.3 44.3 203 203 12 VDC 33.3 33.3 360 360 24 VDC 16.7 16.7 1,440 1,440 Low-sensitivity Must set voltage (V) Must reset voltage (V) % of rated voltage Load Item Contact type Bifurcated crossbar Contact material Rated load Rated carry current Inductive load (cosφ = 0.4; L/R = 7 ms) Resistive load Ag (Au-Alloy) 0.4 A at 125 VAC; 2 A at 30 VDC 0.2 A at 125 VAC; 1 A at 30 VDC 3A Max. switching voltage 250 VAC, 220 VDC Max. switching current 3A 2 Power consumption Set coil (mW) Reset coil (mW) 70% max. 70% max. 190% (at 23°C) Approx. 200 Approx. 200 70% max. 70% max. 170% (at 23°C) Approx. 400 Approx. 400 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. 4. Refer to the engineering data for relations between the ambient temperature and maximum coil voltage. ●Contacts Max. voltage (V) G6E Low Signal Relay ■Characteristics (Including Models for Ultrasonically Cleanable) Item Relay Function Contact resistance *1 Operate (set) time Release (reset) time Min. set pulse width Min. reset pulse width Insulation resistance *2 Impulse withstand Between coil and contacts voltage Between contacts of same polarity Between coil and contacts Dielectric strength Between contacts of same polarity Destruction Vibration resistance Malfunction Destruction Shock resistance Malfunction Mechanical Durability Single-side Stable Single-winding Latching 50 mΩ max. 5 ms max. 5 ms max. − − Double-winding Latching 15 ms 15 ms 1,000 MΩ min. (at 500 VDC) 2,500 V (10×160 μs) (conforms to FCC part 68) 1,500 V (10×160 μs) (conforms to FCC part 68) 1,500 VAC, 50/60 Hz for 1 min 1,000 VAC, 50/60 Hz for 1 min 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) 1,000 m/s2 300 m/s2 100,000,000 operations min. (at 36,000 operations/hr) 100,000 operations min. (0.4 A at 125 VAC resistive load; 0.2 A at 125 VAC inductive load) (at 1,800 operations/hr) 500,000 operations min. (2 A at 30 VDC resistive load; 1 A at 30 VDC inductive load) (at 1,800 operations/hr) 200,000 operations min. (3 A at 30 VDC resistive load) (at 1,800 operations/hr) 10 μA at 10 mVDC -40°C to 70°C (with no icing or condenstion) 5% to 85% Approx. 2.7 g Electrical Failure rate (P level) (reference value) *3 Ambient operating temperature Ambient operating humidity Weight Note: The values here are initial values. *1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method. *2. The insulation resistance was measured with a 500 VDC Megger Tester applied to the same parts as those used for checking the dielectric strength. *3. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions. ■Engineering Data 5 DC resistive load 3 2 AC resistive load 1 DC inductive load (L/R = 7 ms) 0.5 0.4 0.3 0.2 AC inductive load (cosφ = 0.4) 0.05 0.03 3 5 10 10,000 5,000 3,000 30 VDC inductive load (L/R = 7 ms) 1,000 500 30 VDC resistive load 300 20 30 50 100 280 260 G6E-134P-US G6EK-134P-US G6EU-134P-US 240 220 200 180 5 0 0.2 0.4 300 500 1,000 1 G6E-134PL-US G6EK-134PL-US G6EU-134P-US Only at 48VDC 160 100 125 VAC resistive 50 load 30 125 VAC inductive load 10 (cosφ = 0.4) 0.1 0.01 0 ●Ambient Temperature vs. Maximum Coil Voltage Maximum coil voltage (%) 10 ●Durability Durability (x104 operations) Switching current (A) ●Maximum Switching Power 140 120 100 2 3 4 0 -50 -40 -20 0 20 Switching current (A) Switching voltage (V) 40 60 80 100 Ambient temperature (°C) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. ●Shock Malfunction G6E-134P-US 100 De-energized Coil is applied with 130% of rated voltage Y G6EK-134P-US Reset 1,000 Y 1,000 Set Energized 80 40 20 Coil is applied with 100% of rated voltage Hot start voltage (max. value) Cold start voltage (max. value) Release voltage at hot start (min. value) Release voltage at cold start (min. value) 500 0 600 1,000 Z' X' 1,000 1,000 0 -40 Voltage not applied to the coil and contacts -20 0 20 40 60 80 100 120 Shock direction X X' Y Z Z' Y' Y' Unit: m/s2 Sample: G6E-134P-US 24 VDC Number of Relays: 10 pcs Z 1,000 600 0 700 1,000 Z' 1,000 Y' Unit: m/s2 Sample: G6EK-134P-US 12 VDC Number of Relays: 20 pcs Shock direction X X' Y Z Z' Y' X' 1,000 Coil terminal Voltage not applied to the coil and contacts X 1,000 Z 1,000 Contact terminal 60 X 1,000 Coil terminal Coil is applied with 100% of rated voltage Contact terminal On the basis of rated voltage (%) ●Ambient Temperature vs. Must Operate or Must Release Voltage Ambient temperature (°C) Test Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunction. 3 G 6 E G6E Low Signal Relay ●Contact Reliability Test (70°C) *1, *2 G6E-134P-US 60 50 40 Must 30 release voltage 20 min. Sample: G6E-134P-US 24 VDC Number of Relays: 10 pcs Test conditions: Resistive load at 10 VDC 0.01 mA Switching frequency: 1,800 operations/h max. min. 10 Contact resistance (mΩ) 100 70 50 NO contact NC contact max. 30 min. min. 10 30 50 100 300 500 1,000 3,000 5,000 Operating frequency (×104 operations) G 6 E 0 Sample: G6E-134P Number of Relays: 5 pcs NC contact 20 2.54 mm 60 min. 50 5.08 mm 40 max. 30 Must release voltage Relays other than the testing models are de-energized 20 min. Sample: G6E-134P-US 24 VDC Number of Relays: 10 pcs Test conditions: Resistive load at 5 VDC 1 mA Switching frequency: 120 operations/min NO contact NC contact max. 10 30 5.08 mm min. 10 0.1 0.3 0.5 1 3 5 10 30 50 100 300 500 Rotation (×104 turns) ●High-frequency Characteristics (Insertion Loss) *1, *3 (Average value (initial)) G6E-134P-US Insertion loss (dB) Isolation (dB) ●High-frequency Characteristics (Isolation) *1, *3 (Average value (initial)) G6E-134P-US max. 70 Must operate voltage 100 70 50 max. Must operate voltage Must release voltage 80 Relays other than the testing models are de-energized Change rate on the basis of initial value (%) max. ●Mutual Magnetic Interference G6E-134P-US 2.54 mm Change rate on the basis of initial value (%) 70 Must operate voltage Contact resistance (mΩ) On the basis of rated voltage (%) 80 On the basis of rated voltage (%) ●Contact Reliability Test *1, *2 G6E-134P-US Initial stage Test 2.0 1.0 0 −1.0 −2.0 Average value Initial stage Test 2.0 1.0 0 −1.0 −2.0 Average value 0 Sample: G6E-134P Number of Relays: 5 pcs NC contact 1 40 2 NO contact NO contact 60 3 80 1 10 100 4 1 1,000 10 100 50 Sample: G6E-134P-US Number of Relays: 100 pcs Test conditions: 100% of 40 coil voltage applied Must operate time Must release time G6E-134PL-US Number of contacts Number of contacts ●Must Operate and Must Release Time Distribution *1 G6E-134P-US G6E-134P-US 48 VDC 100 Sample: G6E-134PL-US Number of Relays: 100 pcs Test conditions: 100% of 80 coil voltage applied Must operate time Must release time 100 Sample: G6E-134P-US 48 VDC Number of Relays: 100 pcs 40 Test conditions: 100% of coil voltage applied 60 30 20 40 20 10 20 10 1.0 1.2 1.4 1.6 1.8 2.1 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 0 1 2 3 4 Time (ms) ●Distribution of Bounce Time *1 G6E-134P-US Operating bounce time Release bounce time 20 10 10 0.3 Time (ms) 0.4 Time (ms) Release bounce time *1. *2. 20 0.2 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Operating bounce time Sample: G6E-134PL-US 12 VDC 40 Number of Relays: 50 pcs 30 0.1 Must release time 50 30 0 Must operate time G6E-134PL-US 50 Sample: G6E-134P-US 12 VDC 40 Number of Relays: 50 pcs 0 5 Time (ms) Number of contacts Number of contacts 50 30 0 4 1,000 Frequency (MHz) Frequency (MHz) Number of contacts 100 0 *3. 0.3 0.6 0.9 1.2 1.5 1.8 2.1 Time (ms) The tests were conducted at an ambient temperature of 23°C. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics, including durability, in the actual machine before use. G6E Low Signal Relay ■Dimensions Single-side stable G6E-134P-US G6E-134PL-US G6E-134P-US-U G6E-134PL-US-U PCB Mounting Holes (Bottom View) Tolerance: ±0.1 16max. (15.9)* Five, 1.0 dia. holes 2.54 10max. (9.9)* Terminal Arrangement/ Internal Connections (Bottom View) (1.19) 2.54 7.62 12 3.5 0.6 1.6 0.25 5.08 7.62 7.62 * Average value Single-winding latching G6EU-134P-US G6EU-134P-US-U (1.65) 5.08 7.62 Terminal Arrangement/ Internal Connections (Bottom View) Five, 1.0 dia. holes (1.19) 2.54 8max. 0.3 (7.9)* +1 − 7.62 12 0.6 Double-winding latching G6EK-134P-US G6EK-134PL-US G6EK-134P-US-U 0.25 5.08 7.62 7.62 * Average value (1.65) 5.08 (1.19) 7.62 0.25 5.08 7.62 7.62 * Average value G 6 E Terminal Arrangement/ Internal Connections (Bottom View) 3.5 0.6 7 Six, 1.0 dia. holes 2.54 8max. 0.3 (7.9)* 1.6 10 −6 + 7.62 2.54 10max. (9.9)* R Note: Orientation marks are indicated as follows: PCB Mounting Holes (Bottom View) Tolerance: ±0.1 16max. (15.9)* S Note: Be sure to confirm coil polarity. 3.5 1.6 7 Note: Orientation marks are indicated as follows: 2.54 10max. (9.9)* 10 Note: Be sure to confirm coil polarity. PCB Mounting Holes (Bottom View) Tolerance: ±0.1 16max. (15.9)* −6 1+ 8max. 0.3 (7.9)* (1.65) 5.08 7.62 +1 S 3 − R6 + 12 10 7 Note: Be sure to confirm coil polarity. The model G6EK-134P-1-US has positive (+) terminal #3 and negative (-) terminals #1 and #6. Note: Orientation marks are indicated as follows: 5 G6E Low Signal Relay ■ Approved Standards • The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values before use. UL recognized: (File No. E41515) CSA certified: (File No. LR31928) Contact Coil ratings form Model G6E( )-134P( )US SPDT (1c) 5 to 48 VDC Contact ratings Number of test operations 0.2 A, 250 VAC 0.6 A, 125 VAC 2 A, 30 VDC 0.6 A, 125 VDC 6,000 ■Precautions ● Please refer to “PCB Relays Common Precautions” for correct use. Correct Use G 6 E ● Long-term Continuously ON Contacts • Using the Relay in a circuit where the Relay will be ON continuously for long periods (without switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation, causing a film to develop on the contact surfaces. We recommend using a latching relay (magnetic-holding relay) in this kind of circuit. If a single-side stable model must be used in this kind of circuit, we recommend using a fail-safe circuit design that provides protection against contact failure or coil burnout. ● Mounting • Do not reverse the polarity of the coil (+, −). • Provide sufficient space between Relays when mounting two or more on the same PCB, as shown in the following diagram. ● Wiring • Refer to the following diagram when wiring to switch a DC load. The difference in polarity applied to the contacts will affect the endurance of the Relay due to the amount of contact movement. To extend the endurance characteristics beyond the performance ratings, wire the common (pin 7) terminal to the positive (+) side. + − 12 Load ● Relay Handling • When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature to less than 40°C. Do not put the Relay in a cold cleaning bath immediately after soldering. 7 10 Load Wiring Diagram ● Ultrasonic Cleaning • Do not use ultrasonic cleaning on standard relay models. Doing so may result in resonance, coil burnout, and contact adhesion within the Relay. Use a model designed for ultrasonic cleaning if ultrasonic cleaning is required. Close mounting Distance between terminals: 2.54 × 2 (pitch) max. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 6 Contact: www.omron.com/ecb Cat. No. K024-E1-11 0617(0207)(O)
G6E-134P-US DC12 价格&库存

很抱歉,暂时无法提供与“G6E-134P-US DC12”相匹配的价格&库存,您可以联系我们找货

免费人工找货
G6E-134P-US DC12
    •  国内价格
    • 33+26.05806

    库存:44